28
10. Technical Data
THE COOKER IS CATEGORY: II
2H3+.
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: GB, IE.
Connections
Gas (Rp ½ at rear right-hand side) Electric
Natural gas 20mbar
230 / 400V 50HzButane 29mbar
Propane 37mbar
See the appliance badge for test pressures.
Dimensions
Overall height minimum 912mm maximum 937mm
Overall width 1092mm
Overall depth 610mm (to fascia); 670mm (including handles)
Minimum height above the hotplate 800 mm
Refer to 'Positioning the Cooker'.
Ratings
Hotplate Bypass Screw**
Natural Gas 20mb LP Gas
Injector Injector
Centre burner 57 5.0kW 165 4.0kW (291g/h) 107*
Large burner 40 3.0kW 120 3.0kW (214g/h) 82
Right-hand front
burner
32 1.7kW 95 1.7kW (121 g/h) 64
* This is a special non-counterbored jet. Gas inputs based on Gross Caloric Value.
** The valves in this cooker are tted with adjustable bypass screws. The cooker is supplied with the bypass screws set for
Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Oven Efficiency
Ovens
Left-hand Oven Right-hand Oven
Multi-function Forced Air Convection
Maximum power output @ 230 V 50 Hz 2.5 kW 2.5 kW
Energy eciency class on a scale of A (more ecient) to G (less ecient) A A
Energy consumption based on standard load 0.95kWh 0.90kWh
Usable volume (litres) 78 78
Size Large Large
Time to cook standard load 41 minutes 38 minutes
Surface area of the grid 1400cm
2
1400cm
2
Grill 2.3 W
Maximum total electrical load at 230V (approximate total including oven lights, oven fan, etc.): 7.4kW